Hip Fracture Management Solutions
Intracapsular fractures
Total hip replacement (THR) can offer clinical benefits over traditional internal fixation (IF) or hemiarthroplasty (HA) solutions in the treatment of intracapsular hip fracture. Patients treated with THR have demonstrated better health outcomes(1,2) and a significantly lower occurrence of increased pain levels at both 1 and 13 year intervals than those treated with HA(3), as well as having fewer major re-operations(4) and a lower risk of mortality(5).

Complementing our suite of THR prostheses, Corin also offers a wide range of traditional and progressive solutions for fracture management, fulfilling the needs of all clinicians.
![]() |
MetaFixFounded on 20 years' experience in cementless technology and high performance bearings, and with a proven, world-leading stem design. |
![]() |
TaperFitA double-tapered, polished, collarless stem, based on biomechanical principles proven over 20 years of clinical use. |
![]() |
Thompson and Austin MooreAvailable in titanium alloy or cobalt chrome, the Thompson and Austin Moore prostheses are available in standard and narrow stem options. |
![]() |
DHS ScrewThe Corin DHS screw features a keyless lag screw for improved strength – a ‘double flat’ lag screw design for half-turn adjustment. |
![]() |
Hemiarthroplasty headsModular hemiarthroplasty heads are available in 1mm size increments with short, standard and long necks to reproduce all types of patient anatomy. |
![]() |
Bipolar headsBased on a self-centring eccentric design, Corin pre-assembled bipolar heads are comprised of an outer cobalt chrome shell with inner polyethylene liner. |
References:
1. Blomfeldt R, Tornkvist H, Ponzer S, Soderqvist A, Tidermark J. Comparison of internal fixation with total hip replacement for displaced femoral neck fractures. Randomized controlled trial performed at four years. J Bone Joint Surg [Am] 2005;87:1680-8.
2. Keating JF, Grant A, Masson M, Scott NW, Forbes JF. Randomized comparison of reduction
and fixation, bipolar hemiarthroplasty and total hip arthroplasty, treatment of displaced intracapsular hip fractures in healthy older patients. J Bone Joint Surg [Am] 2006;88:249-60.
3. Ravikumar KJ, Marsh G. Internal fixation versus hemiarthroplasty versus total hip arthroplasty for displaced subcapital fractures of the femur – 13 year results of a prospective randomised study. Injury 2000; 31:793-7.
4. Baker RP, Squires B, Gargan MF, Bannister GC. Total hip arthroplasty and hemiarthroplasty in mobile, independent patients with a displaced intracapsular fracture of the femoral neck. A randomized, controlled trial. J Bone Joint Surg [Am] 2006;88:2583-2589.
5. Parker MJ, Gurusamy KS. Internal fixation versus arthroplasty for intracapsular proximal femoral fractures in adults. Cochrane Database of Systematic Reviews. 2006; 4.
Important: Not all products are available or cleared for distribution in all international markets. For more details, please contact your local subsidiary or distributor by visiting the Corin worldwide section.








