Promote and accelerate osseointegration in cementless fixation

Read More

About


A chemically tailored calcium phosphate coating3,4 which rapidly resorbs1 to promote and accelerate osseointgeration2, a key to achieving long-term fixation without cement.

Rapid

Rapid


This calcium phosphate (CaP) coating, with a tailored chemical composition of brushite and hydroxyapatite, facilitates full and rapid resorption1 to accelerate and promote osseointegration for long-term implant stability. 

The coating has a crystalline structure with good capillarity properties, beneficial to the absorption of these growth factors and adhesion of bone cells3.

Total coverage

Total coverage


An electrolytic deposition process, unlike most conventional ‘line of sight’ processes, produces a fine, uniform layer for total coverage of the exposed surfaces or structures. This maintains substrate roughness4 and provides a large area for osseointegration3.

Proven

Proven


With over 25 years of clinical history2,3,4 this coating is proven in orthopaedics.

Both Corin implants use this coating to promote and accelerate osteointegration, leading to excellent clinical performance5,6

Trinity PLUS for example, successfully uses this coating to accelerate bone growth and osseointegration7, in scenarios where typically it would be hard to achieve given the poor bone quality. 

References


  1. Evaluation of implant fixation in an ovine model – Corin. Professor W.R. Walsh Ph.D.
  2. Wood PLR, Deakin S. Total ankle replacement. The results in 200 ankles. J Bone Joint Surg (Br) 2003; 85-B:3:334.
  3. Saxler G, Temmen D, Bontemps G. Medium-term results of AMC-unicompartmental knee arthroplasty. The Knee 2004; 11:39-355.
  4. Schlueter-Brust KU, Kruse S, Bontemps G. Twelve year survivorship after cemented and uncemented medial unicompartmental knee arthroplasty. 15th EFFORT Congress June 2014.
  5. National Joint Registry 16th Annual Report 2019.
  6. Australian Orthopaedic Association National Joint Replacement Registry Annual Report 2018.
  7. Data on file, Corin Group Ltd.
Request more information

Request more information

Important information


Not all products are available or cleared for distribution in all markets. For more details please contact us.